Home | Showroom | Percent Rated Output | Testing Equipment | Contact us
If we don't have it. we will make it

German
Spanish
French
Italian
Portuguese
Japanese
Korean
Arabic
Russian
Croatia
 
  Water treatment uv lamps
 
  Air purifier uv lamps
 
  Aquarium UV lamps
 
  Quartz sleeves
 
  Nail gel curing lamps
 
  Curing lamps
 
  Ballast
 
  Other UV lamps
 
SaniLight Commercial Models & Lamp Data
Sanilight Germicidal Ultraviolet Irradiators 05-1500-R,05-1340-R,05-1348-R,05-1352-R,05-1343-R,05-1334-R,05-1338A-R,05-1500-R(2),05-1340-R(2),05-1348-R(2),05-1352-R(2),05-1343-R(2),05-1334-R(2),05-1338A-R(2),05-0052a,05-0040,05-1118,05-0044,05-0042-R,05-0040(2),05-1118(2),05-0044(2),05-0042-R(2),05-0042-R(4) SLIMLINE GERMICIDAL LAMPS

Model Lamp Total
Ultraviolet
Output (1)
Dimensions

Rated Average
Lamp Life

Length Width Height
D 12-1S 05-1500-R 3.1 Watts 13-1/4" 5" 3-3/4" 10,000 Hours
D 18-1S 05-1340-R 5.8 Watts 19-1/4" 5" 3-3/4" 10,000 Hours
D 24-1S 05-1348-R 8.5 Watts 25-1/4" 5" 3-3/4" 10,000 Hours
D 30-1S 05-1352-R 11.2 Watts 31-1/4" 5" 3-3/4" 10,000 Hours
D 36-1S 05-1343-R 13.8 Watts 37-1/4" 5" 3-3/4" 10,000 Hours
D 48-1S 05-1334-R 19.3 Watts 49-1/4" 5" 3-3/4" 10,000 Hours
D 64-1S 05-1338A-R 25.0 Watts 65-1/4" 5" 3-3/4" 10,000 Hours
D 12-2S 05-1500-R (2) 6.2 Watts 13-1/4" 5" 3-3/4" 10,000 Hours
D 18-2S 05-1340-R (2) 11.6 Watts 19-1/4" 5" 3-3/4" 10,000 Hours
D 24-2S 05-1348-R (2) 17.0 Watts 25-1/4" 5" 3-3/4" 10,000 Hours
D 30-2S 05-1352-R (2) 22.4 Watts 31-1/4" 5" 3-3/4" 10,000 Hours
D 36-2S 05-1343-R (2) 27.6 Watts 37-1/4" 5" 3-3/4" 10,000 Hours
D 48-2S 05-1334-R (2) 38.6 Watts 49-1/4" 5" 3-3/4" 10,000 Hours
D 64-2S 05-1338A-R (2) 50.0 Watts 65-1/4" 5" 3-3/4" 10,000 Hours
(1) Ultraviolet Output at 254 nanometers at 100 hours and 80 degrees F (approximate).
-Standard units are hardwired
-120 Volts 60 Hz and 220 Volts 50 Hz. units are standard - specify when ordering
-Consult factory with other specific power requirements
*Hg - LAMP CONTAINS MERCURY, manage in accord with disposal laws, see: www.lamprecycle.org
Sanilight Germicidal Ultraviolet Irradiators 05-1500-R,05-1340-R,05-1348-R,05-1352-R,05-1343-R,05-1334-R,05-1338A-R,05-1500-R(2),05-1340-R(2),05-1348-R(2),05-1352-R(2),05-1343-R(2),05-1334-R(2),05-1338A-R(2),05-0052a,05-0040,05-1118,05-0044,05-0042-R,05-0040(2),05-1118(2),05-0044(2),05-0042-R(2),05-0042-R(4)COLD CATHODE GERMICIDAL LAMPS
Model Lamp Total
Ultraviolet
Output (1)
Dimensions

Rated Average
Lamp Life

Length Width Height
D 12-1CC 05-0052a 1.4 Watts 13-1/4" 5" 3-3/4" 20,000 Hours
D 18-1CC 05-0040 3.2 Watts 19-1/4" 5" 3-3/4" 20,000 Hours
D 24-1CC 05-1118 5.0 Watts 25-1/4" 5" 3-3/4" 20,000 Hours
D 36-1CC 05-0044 8.5 Watts 37-1/4" 5" 3-3/4" 20,000 Hours
D 48-1CC 05-0042-R 11.2 Watts 49-1/4" 5" 3-3/4" 20,000 Hours
D 18-2CC 05-0040 (2) 6.4 Watts 19-1/4" 6" 3-3/4" 20,000 Hours
D 24-2CC 05-1118 (2) 10.0 Watts 25-1/4" 6" 3-3/4" 20,000 Hours
D 36-2CC 05-0044 (2) 17.0 Watts 37-1/4" 6" 3-3/4" 20,000 Hours
D 48-2CC 05-0042-R (2) 22.4 Watts 49-1/4" 6" 3-3/4" 20,000 Hours
D 48-4CC 05-0042-R (4) 44.8 Watts 49-1/4" 8-1/2" 3-3/4" 20,000 Hours
(1) Ultraviolet Output at 254 nanometers at 100 hours and 80 degrees F (approximate).
-Standard units are hardwired
-120 Volts 60 Hz and 220 Volts 50 Hz. units are standard - specify when ordering
-Consult factory with other specific power requirements

Home | About Us | Showroom | Percent Rated Output | Testing Equipment | Contact us
©Suzhou Xicheng Water Treatment Equipment Co., Ltd.